Henry® Blueskin® Metal Clad® is a self-adhered water resistive air barrier membrane comprised of rubberized asphalt and dual-layers of high strength polyethylene with surface layer of metallic aluminum film. Due to its metallic surfacing, Blueskin Metal Clad exhibits excellent weathering resistance when applied to above-grade wall assemblies. This vapour impermeable membrane is available in various roll widths for both membrane and flashing applications and has a removable release liner for ease of installation.

Features

  • Permanent UV exposure under open joint cladding
  • Can be left exposed for up to 12 months during construction
  • Aluminum surfacing offers ideal substrate for adhesion of construction sealants
  • Compatible with other Henry air barrier system components
  • Compliant in various NFPA 285 wall assemblies
  • Low temperature application down to 20 °F (-7 °C)
  • Living Building Challenge Declare label (Red List Free)
  • 100% solids - No VOC's
  • Vertical and lateral flame propagation: meets NFPA 285 Exception #2 per ASTM E1354 and ASTM E84

Packaging options

  • Thickness - 40 mils
  • Roll width - 4", 6", 9", 12", 18" and 36"
  • Roll length - 66.7 ft. roll

 

Air Barrier Brochure

Commercial Air Barrier Systems Brochure

Download PDF

 
Air Barrier Brochure

Commercial Air Barrier Systems Selection Chart

Download PDF

 
Blueskin Metal Clad Declare Label

Blueskin® Metal Clad® Declare Label

Download PDF

 

Data Sheets

Blueskin® Metal Clad® Data Sheet Download PDF      
 

SDS Sheets

Blueskin® Metal Clad® SDS Sheet Download PDF      
 

Product Certification

Blueskin® Metal Clad® Product Certification Download PDF      
 

Tech Talks

Henry® Air Barrier Assemblies Meet ASTM E2357 Download PDF      
Henry® Living Building Challenge: Red List Status Download PDF      
Henry® NFPA 285 Air Barrier Assemblies Download PDF      
Henry® Self-Adhered, Rubberized Asphaltic Membranes / Chemical Compatibility Download PDF      
Henry® Self-Adhered and Fluid Applied Water Resistive Air Barrier earns Living Building Challenge Declare “Red List Free” Status Download PDF      
Henry® Air Barriers NFPA 285 Exception 2  Download PDF      

Health Product Declaration

Blueskin® Metal Clad® Health Product Declaration Download PDF      
         

 

Air Barrier Brochure

Commercial Air Barrier Systems Brochure

Download PDF

 
Air Barrier Brochure

Commercial Air Barrier Systems Selection Chart

Download PDF

 
Blueskin Metal Clad Declare Label

Blueskin® Metal Clad® Declare Label

Download PDF

 

Specifications

Blueskin® Metal Clad® Self Adhered Water Resistive Air Barrier Section 07 27 00 Download Word File      

Architectural Details

MTLCLD-1A Wall Foundation Slab Below Grade Download PDF   Download DWG  
MTLCLD-1B Wall Foundation Slab on Grade Download PDF   Download DWG  
MTLCLD-1C Wall Foundation Transition No Brick Ledge Download PDF   Download DWG  
MTLCLD-2A Pipe Penetration 0.5 Inch Wide Gap Max Download PDF   Download DWG  
MTLCLD-2B Pipe Penetration 0.75 Inch Wide Gap Max Download PDF   Download DWG  
MTLCLD-3A Inside and Outside Corners Download PDF   Download DWG  
MTLCLD-3B Inside and Outside Corners Download PDF   Download DWG  
MTLCLD-4A Substrate Transition Download PDF   Download DWG  
MTLCLD-4B Substrate Transition Download PDF   Download DWG  
MTLCLD-5A Thru-Wall Flashing Download PDF   Download DWG  
MTLCLD-6A-A Flanged Window Section Method A Download PDF   Download DWG  
MTLCLD-6A-B Flanged Window Sequence Installation Method A Download PDF   Download DWG  
MTLCLD-6A1-A Flanged Window Section Method A1 Download PDF   Download DWG  
MTLCLD-6A1-B Flanged Window Sequence Installation Method A1 Download PDF   Download DWG  
MTLCLD-6B-A Non-Flanged Window Section Method B Download PDF   Download DWG  
MTLCLD-6B-B Non-Flanged Window Sequence Installation Method B Download PDF   Download DWG  
MTLCLD-6B1-A Non-Flanged Window Section Method B1 Download PDF   Download DWG  
MTLCLD-6B1-B Non-Flanged Window Sequence Installation Method B1 Download PDF   Download DWG  
MTLCLD-6C Door Frame Section Download PDF   Download DWG  
MTLCLD-7A Reverse-Lap Download PDF   Download DWG  
MTLCLD-8A Construction Joints 0.5-Inch Gap Max Download PDF   Download DWG  
MTLCLD-8B Construction Joints 1-Inch Gap Max Download PDF   Download DWG  
MTLCLD-8C Construction Joints 2-Inch Gap Max Download PDF   Download DWG  
MTLCLD-8D Deflection Joint Download PDF   Download DWG  
MTLCLD-8E Cracks 0.5-Inch Gap Max Download PDF   Download DWG  
MTLCLD-9A Roofing Wrapping Parapet Download PDF   Download DWG  
MTLCLD-9B Air Barrier Transition at Parapet Download PDF   Download DWG