Specifications
|
Blueskin® VP160 Guide Spec |
 |
|
|
|
Architectural Details
|
Blueskin® VP160 - 1A Wall Foundation - Exterior wall and foundation transtion - Slab below grade |
 |
|
 |
|
Blueskin® VP160 - 1B Wall Foundation - Exterior wall and foundation transtion - Slab on grade |
 |
|
 |
|
Blueskin® VP160 - 2A Pipe penetration - Substrate gaps up to 1/2" wide gap maximum - 212 All Purpose Crystal Clear Sealant |
 |
|
 |
|
Blueskin® VP160 - 2B Pipe penetration - Substrate gaps up to 1/2" wide gap maximum - Air-Bloc® LF Liquid-Applied flashing |
 |
|
 |
|
Blueskin® VP160 - 2C Pipe penetration - Substrate gaps up to 3/4" wide gap maximum - Self-adhered flashing |
 |
|
 |
|
Blueskin® VP160 - 3A Inside and outside corners |
 |
|
 |
|
Blueskin® VP160 - 4A Column transition - Transition of dissimilar substrate materials - Self-adhered flashing |
 |
|
 |
|
Blueskin® VP160 - 5A Thru-wall flashing - Transition or dissimilar substrate materials - Blueskin® TWF self-adhered thru-wall flashing |
 |
|
 |
|
Blueskin® VP160 - 6A Rebate window - Self-adhered or liquid applied flashing |
 |
|
 |
|
Blueskin® VP160 - 6B1 Rebate window - Self-adhered or liquid applied flashing part 1 of 3 |
 |
|
 |
|
Blueskin® VP160 - 6B2 Rebate window - Self-adhered or liquid applied flashing part 2 of 3 |
 |
|
 |
|
Blueskin® VP160 - 6B3 Rebate window - Self-adhered or liquid applied flashing part 3 of 3 |
 |
|
 |
|
Blueskin® VP160 - 6C1 Flange window - Self-adhered or liquid applied flashing part 1 of 3 |
 |
|
 |
|
Blueskin® VP160 - 6C2 Flanged window - Self-adhered or liquid applied flashing part 2 of 3 |
 |
|
 |
|
Blueskin® VP160 - 6C3 Flanged window - Self-adhered or liquid applied flashing part 3 of 3 |
 |
|
 |
|
Blueskin® VP160 - 7A Reverse lap - Blueskin® VP160 lapping onto Blueskin® VP160 |
 |
|
 |
|
Blueskin® VP160 - 7B Reverse lap - Blueskin® Butyl Flash lapping onto Blueskin® VP160 |
 |
|
 |
|
Blueskin® VP160 - 7C Reverse lap - Blueskin® SA, Metal Clad®, or Blueskin® TWF lapping onto Blueskin® VP160 |
 |
|
 |
|
Blueskin® VP160 - 7D Reverse lap - Special considerations – Blueskin® VP160 lapping onto Blueskin® VP160 |
 |
|
 |
|
Blueskin® VP160 - 8A Substrate gaps - Substrate gaps up to 1/2" wide maximum - No supplemental detail required |
 |
|
 |
|
Blueskin® VP160 - 8B Substrate gaps - Substrate gaps up to 3/4" wide maximum - Self-adhered flashing |
 |
|
 |
|
Blueskin® VP160 - 8C Substrate Gaps - Substrate gaps up to 2" wide maximum - Self-adhered flashing |
 |
|
 |
|
Blueskin® VP160 - 9A Parapet Transition - Air barrier installed on front and back of parapet wall |
 |
|
 |
|
Blueskin® VP160 - 9B Parapet Transition - Roofing assembly wrapping over top of parapet |
 |
|
 |
|